TECVAL CP-04 needle valves are designed to work with liquids under both high pressure and temperature service. Their back-seat allows the free packing change while the valves are in service. They are used to insulate and avoid damaging instruments on the installation, since they do not cause water hammer, thanks to their design.
Maximum Pressure | Standard pressure: 100 bar (1500 PSI) | |
---|---|---|
Temperature Range | -20ºC/400ºC (-4ºF/752ºF) | |
Connections | Threaded NPT (ANSI B1.20.1) | |
Dimensions | 1/4" | 1/2" |
A Open | 89 | 92 |
A Closed | 82 | 82 |
B | 12.5 | 15 |
C (GAS-BSP) | 63 | 75 |
C (NPT) | 63 | 70 |
Orifice Size (DN) | 2.5 | 2.5 |
Flow Coefficient (Cv) | 0.1 | 0.1 |
Materials | Brass (1.7660) Carbon Steel (1.1158) AISI-316L (1.4404) Special alloys (For detailed information consult attached data sheet) |