Catalogue

Fittings

CMR-06 - TECVAL,S.L., 2024 all rights reserved.
CMR
Threaded Male Connector NPT

The CMR two-ferrule compressing fittings are used to assemble a threaded end to a metric or fractional tube. The resulting union is completely hermetic, both for high pressure and high temperatures.

Features

 
Easy and fast mounting.
 
Resistant to vibration.
 
Hard fastening and union without twisting.
 
Anti-leakage guarantee.
 
Metric tube from 6mm to 12mm.
 
Fractional tube from 1/4" to 3/4".
 
Threaded NPT ends according to ANSI B1.20.1.
Technical data
Ø ODACode NPTB (mm)L (mm)
61/4"800091638
61/2"800111644
1/4"1/4"800121638
1/4"1/2"800141644
81/4"800171739
3/8"1/4"800191740
3/8"1/2"800211745
101/4"800221741
 
Ø ODACode NPTB (mm)L (mm)
101/2"800241745
121/4"800252343
121/2"800272347
1/2"1/4"800292343
1/2"1/2"800312347
3/4"1/2"800412449
3/4"3/4"800422450
Materials

SuperDuplex (1.4410 / 1.4501).  AS 

AISI-904L (1.4539).  A9 

Cómo pasar pedidos

The fittings references are formed in two parts:
 Fitting Code  Look for it in the technical data.
 Material Code  Look for it in the materials list.
Example: Threaded Male Connector CMR 6mm OD x
1/4"NPT Superduplex will be:  80009   AS  .
The reference required to place the order is  80009AS .

 
Packaging

All TECVAL fittings are supplied packed in individual polyethilene airtight bags. Everything is 100% recyclable.


 
CHR-06 - TECVAL,S.L., 2024 all rights reserved.
CHR
Threaded Female Connector NPT

The CHR two-ferrule compressing fittings are used to assemble a threaded end to a metric or fractional tube. The resulting union is completely hermetic, both for high pressure and high temperatures.

Features

 
Easy and fast mounting.
 
Resistant to vibration.
 
Hard fastening and union without twisting.
 
Anti-leakage guarantee.
 
Metric tube from 6mm to 12mm.
 
Fractional tube from 1/4" to 3/4".
 
Threaded NPT ends according to ANSI B1.20.1.
Technical data
Ø ODACode NPTB (mm)L (mm)
61/4"804091636
61/2"804111643
1/4"1/4"804121636
1/4"1/2"804141643
81/4"804171733
3/8"1/4"804191739
3/8"1/2"804211733
101/4"804221738
 
Ø ODACode NPTB (mm)L (mm)
101/2"804241744
121/4"804252340
121/2"804272346
1/2"1/4"804292340
1/2"1/2"804312346
3/4"1/2"804412447
3/4"3/4"804422448
Materials

SuperDuplex (1.4410 / 1.4501)  AS 

AISI-904L (1.4539)  A9 

Ordering information

The fittings references are formed in two parts:
 Fitting Code  Look for it in the technical data.
 Material Code  Look for it in the materials list.

Example: Threaded Female Connector CHR 1/2"OD x 1/4"NPT Superduplex will be:  80425   AS .

The reference required to place the order is 80425AS.

 
Packaging

All TECVAL fittings are supplied packed in individual polyethilene airtight bags. Everything is 100% recyclable.


 
CIR-03 - TECVAL, S.L., 2022 all rights reserved.
CIR
Tube connector

The CIR two-ferrule compressing fittings are used to join two metric or fractional tubes of the same outside diameter without either thread or welding. The resulting union is completely hermetic, both for high pressure and high temperatures.

Features

 
Easy and fast mounting.
 
Resistant to vibration.
 
Hard fastening and union without twisting.
 
Anti-leakage guarantee.
 
Metric tube from 6mm to 12mm.
 
Fractional tube from 1/4" to 3/4".
Technical data
Ø OD1CodeB1 (mm)L (mm)
6808111641
8808151641
1/4"808231744
 
Ø OD1CodeB1 (mm)L (mm)
3/8"808271746
10808311747
12808362251
 
Ø OD1CodeB1 (mm)L (mm)
1/2"808422251
3/4"808522453
Materials

SuperDuplex (1.4410 / 1.4501)  AS 

AISI-904L (1.4539)  A9 

Ordering information

The fittings references are formed in two parts:
 Fitting Code  Look for it in the technical data.
 Material Code  Look for it in the materials list.

 

Example: Tube Connector CIR 1/2"OD x 1/2"OD Duplex will be:  80842   AS .

The reference required to place the order is 80842AD.

 
Packaging

All TECVAL fittings are supplied packed in individual polyethilene airtight bags. Everything is 100% recyclable.


 
CIC-04 - TECVAL,S.L., 2022 all rights reserved.
CIC
Elbow Tube Connector

The CMC two-ferrule compressing fittings are used to assemble on 90º two metric or fractional tube. The resulting union is completely hermetic, both for high pressure and high temperatures.

Features

 
Easy and fast mounting.
 
Resistant to vibration.
 
Hard fastening and union without twisting.
 
Anti-leakage guarantee.
 
Metric tube from 6mm to 12mm.
 
Fractional tube from 1/4" to 3/4".
Technical data
Ø ODCodeL (mm)B (mm)
6832032716
1/4"832042716
8832062917
 
Ø ODCodeL (mm)B (mm)
3/8"832073117
10832083117
12832093623
 
Ø ODCodeL (mm)B (mm)
1/2"832103623
3/4"832144024
Materials

SuperDuplex (1.4410 / 1.4501)  AS  

AISI-904L (1.4539)  A9 

 

Assembly parts: Body, Nut, Back ferrule, Front ferrule.

Ordering information

The fittings references are formed in two parts:
 Fitting Code  Look for it in the technical data.
 Material Code  Look for it in the materials list.

 Example: Elbow tube connector CIC 1/2"OD AISI-316L will be:  83210   A4 .

The reference required to place the order is 83210A4.

 
Packaging

All TECVAL fittings are supplied packed in individual polyethilene airtight bags. Everything is 100% recyclable.


 
CIT-03 - TECVAL,S.L., 2022 all rights reserved.
CIT
Tee Tube Connector

The CIT two-ferrule compressing fittings are used to join three metric or fractional tube. The resulting union is completely hermetic, both for high pressure and high temperatures.

Features

 
Easy and fast mounting.
 
Resistant to vibration.
 
Hard fastening and union without twisting.
 
Anti-leakage guarantee.
 
Metric tube from 6mm to 12mm.
 
Fractional tube from 1/4" to 3/4".
Technical data
Ø ODCodeL (mm)B (mm)
6852032716
1/4"852042716
8852062917
 
Ø ODCodeL (mm)B (mm)
3/8"852073117
10852083117
12852093623
 
Ø ODCodeL (mm)B (mm)
1/2"852103623
3/4"852144024
Materials

SuperDuplex (1.4410 / 1.4501)  AS 

AISI-904L (1.4539)  A9 

 

Assembly parts: Body, Nut, Back ferrule, Front ferrule. 

Ordering information

The fittings references are formed in two parts:
 Fitting Code  Look for it in the technical data.
 Material Code  Look for it in the materials list.
Example: Tee Tube Connector CIT of 12 mm.OD AISI-904L will be:  85209   A9 

The reference required to place the order is 85209A9.

 
Packaging

All TECVAL fittings are supplied packed in individual polyethilene airtight bags. Everything is 100% recyclable.


 
CME-05 - TECVAL,S.L., 2024 all rights reserved.
CME
Male Tube Connection NPT

 The CME Adapter is used to connect easily two pipes or components with two-ferrule compression connection in one site and threaded connection in the other site

Features

 
Easy and fast mounting.
 
Resistant to vibration.
 
Hard fastening and union without twisting.
 
Anti-leakage guarantee.
 
Metric tube from 6mm to 12mm.
 
Fractional tube from 1/4" to 3/4".
 
Threaded NPT ends according to ANSI B1.20.1.
Technical data
AODCode NPTL (mm)B (mm)
1/4"6870073616
1/4"1/4"870113616
1/4"8870153617
1/4"3/8"870193717
1/2"3/8"870214317
1/4"10870233717
 
AODCode NPTL (mm)B (mm)
1/2"10870254317
1/2"12870284823
1/4"1/2"870294323
1/2"1/2"870314823
1/2"3/4"870415024
3/4"3/4"870425324
Materials

SuperDuplex (1.4410 / 1.4501)  AS 

AISI-904L (1.4539)  A9 

Ordering information

The fittings references are formed in two parts:
 Fitting Code  Look for it in the technical data.
 Material Code  Look for it in the materials list.


Example: Threaded Male Connector CMR 1/4"OD x 1/4"NPT Superduplex will be:  80012   AS .

The reference required to place the order is 80012AS.

 
Packaging

All TECVAL fittings are supplied packed in individual polyethilene airtight bags. Everything is 100% recyclable.


 
CHE-05 - TECVAL, S.L., 2024 all rights reserved.
CHE
Tube Adapter to Female Threaded NPT

The CME Adapter is used to join a threaded end to a two-ferrule compression fitting. The resulting joint is totally hermetic at high pressure and temperature.

Features

 
Easy and fast mounting.
 
Resistance to vibration.
 
Hard fastening and union without twisting.
 
Anti-leakage guarantee.
 
Metric tube from 6mm. to 12mm.
 
Fractional tube from 1/4" to 3/4".
 
Threaded NPT ends according to ANSI B1.20.1.
Technical data
AODCódigo NPTL (mm)B (mm)
1/4"6873073516
1/4"1/4"873113516
1/4"8873153517
1/4"3/8"873193517
1/2"3/8"873214217
1/4"10873233517
 
AODCódigo NPTL (mm)B (mm)
1/2"10873254217
1/2"12873284823
1/4"1/2"873294123
1/2"1/2"873314823
1/2"3/4"873414924
3/4"3/4"873425124
Materials

SuperDuplex (1.4410 / 1.4501)  AS  

AISI-904L (1.4539)  A9  

Ordering information

The fitting references are fored by two parts:
 Fitting Code  Look for it in the technical data.
 Material  Look for it in the materials list.
Example: CHE 1/4" NPT Female x 6mm. O.D. tube in AISI-904L, would be:
 87307   A9  The reference required to place the order is 87307A9.

 
Packaging

All TECVAL fittings are supplied packed in individual polyethilene airtight bags. Everything is 100% recyclable.


 
CAP-02 - TECVAL,S.L., 2022 all rights reserved.
CAP
Compressing Tube Cap

The CAP two-ferrule compressing fittings are used to block the tube. The resulting union is completely hermetic, both for high pressure and high temperatures.

Features

 
Easy and fast mounting.
 
Resistant to vibration.
 
Hard fastening and union without twisting.
 
Anti-leakage guarantee.
 
Metric tube from 6mm to 12mm.
 
Fractional tube from 1/4" to 3/4".
Technical data
Ø ODCodeL (mm)B (mm)
6860032316
1/4"860042316
8860062417
 
Ø ODCodeL (mm)B (mm)
3/8"860072717
10860082717
12860092923
 
Ø ODCodeL (mm)B (mm)
1/2"860102923
3/4"860143124
Materials

SuperDuplex (1.4410 / 1.4501)  AS 

AISI-904L (1.4539)  A9 

 

Assembly parts: ①Body, ②Nut, ③Back ferrule, ④Front ferrule.

Ordering information

The fittings references are formed in two parts:
 Fitting Code  Look for it in the technical data.
 Material Code  Look for it in the materials list.
Example: Compressing Tube CAP of 12mm.OD AISI-316L will be:
 86009   A4  .The reference required to place the order is 86009A4.

 
Packaging

All TECVAL fittings are supplied packed in individual polyethilene airtight bags. Everything is 100% recyclable.


 
C/Colom, 519 - Pol.Can Parellada - 08228-TERRASSA - Barcelona - SPAIN | Tel: +34 938 280 055 | email: tecval@tecval.es