CP13-04 - TECVAL,S.L., 2021 all rights reserved.
CP-13
Needle Valve with Alignment Sleeve (MxF)
Working Pressures: 100 | 420 bar (1500 | 6000 PSI)

TECVAL CP-13 valves are manufactured following the DIN 16270 AR standard. An alignment coupling incorporated in the design allows to position the instrument. Other features of the valve include a bleed screw, and the back-seat which allows the free packing change in service.

Features

 
Metal-to-metal shut-off.
 
Easy packing external adjustment.
 
Free packing change in service.
 
PTFE packing.
 
100% tested.

Options

 
Grafoil packing for high temperatures.  G 
 
High working pressure 420 bar (6000 PSI)  I 
 
AISI-316 T-Bar handle.  M 
Technical data
Max. Pressure Standard pressure: 100 bar (1500 PSI) High pressure: 420 bar (6000 PSI)
Temperatures -20ºC/400ºC (-4ºF/752ºF)
Dimensions 1/2"
A Open92
A Closed82
B15
C91
Orifice Size (DN) 2.5
Maximum Cv 0.1
Order codes
BSP2404

* Dimensions in mm
Materials
NÂșPartBrass  LA Carbon Steel  AC AISI-316L  A4 Special alloys 
1 Set screwAISI-304 (1.4301)AISI-304 (1.4301)AISI-304 (DIN1.4301)AISI-304 (1.4301)
2 Handle washerAISI-304 (1.4301)AISI-304 (1.4301)AISI-304 (DIN1.4301)AISI-304 (1.4301)
3 Handle wheelBlack painted aluminiumBlack painted aluminiumBlack painted aluminiumBlack painted aluminium
4 NutBrass (1.7660)F-112 (1.1158)AISI-316 (DIN1.4401)AISI-316L (1.4404)
5 GlandBrass (1.7660)F-112 (1.1158)AISI-316 (DIN1.4401)AISI-316L (1.4404)
6 PackingP.T.F.E.P.T.F.E.P.T.F.E. or GrafoilP.T.F.E.
7 BonnetBrass (1.7660)F-112 (1.1158)AISI-316 (DIN1.4401)AISI-316L (1.4404)
8 StemAISI-316L (1.4404)AISI-316L (1.4404)AISI-316 (DIN1.4401)AISI-316L (1.4404)
9 BodyBrass (1.7660)F-112 (1.1158)AISI-316 (DIN1.4401)AISI-316L (1.4404)
10 Alignment sleeveBrass (1.7660)F-112 (1.1158)AISI-316 (DIN1.4401)AISI-316L (1.4404)
11 Bleed screwAISI-316L (1.4404)AISI-316L (1.4404)AISI-316 (DIN1.4401)AISI-316L (1.4404)
Special alloys

Among the wide range of alloys existing, TECVAL has selected those considered by our customers as most suitable, which we stock to ensure a quick and effective supply. Whether you do not find the required alloy or need further information about our exotic alloys valves and fittings, please address your inquiry to our Technical Department.

AISI-316Ti (1.4571)  A6 
AISI-904L (1.4539)  A9 
Duplex (1.4462)  AD 
SuperDuplex (1.4410/1.4501)  AS 
254-SMO (1.4547)  AV 
Titanium Gr.2 (3.7034)  TI 
Hastelloy C-276 (2.4819)  HA 

Ordering information

References are formed by three parts:

 Valve Code 
Look for it in the order codes chart on the previous page.
..  Option/s 
-If required, add the code/s from the options section on the previous page (in alphabetical order)
...  Material 
-Look for the code on the materials chart.


An example of valve and two options:

Needle valve CP-13 1/2"BSP Carbon Steel with grafoil packing:

 2404   G   AC  The reference to place the order is 2404GAC

 

    Tests

100% tested in accordance to API STANDARD 598, each valve is tested to check the leakage in the seats and packing. Upon request, the corresponding materials and test certificates can be delivered with the valve.


Packaging

All TECVAL valves are supplied packed in individual polyethilene airtight bags, which include the general features of the valve. End screw connections are protected with polyethilene caps. Everything is 100% recyclable.


Maintenance

Adjustment of the packing may be necessary during the working life of the valve. The operation consists of turning the nut (4) clockwise.
Valves with long no-working period may have a harder initial operating torque.

C/Colom, 519 - Pol.Can Parellada - 08228-TERRASSA - Barcelona - SPAIN | Tel: +34 938 280 055 | email: tecval@tecval.es